| Description |
- Full Inverter Technology
- ECO-Friendly
- R32 Refrigerant
- Energy Efficient
- WIFI Control
| Anti-condensation
Flocking design, good thermal insulation effect, avoid large temperature difference, anti-condensation
Bigger Air Flow Volume
Innovative centrifugal fan with larger diameter, supply bigger air flow volume and lower noise.
Fresh air
Fresh air intake design to improve air quality.
The independent electric box lid
Easy to connect power line and controller line don't need to disassemble the electric box lid when installation
Easy drainage
Left and right water outlet design of water connection plate, flexible for installation site.
Mid ESP Duct
Built-In Drain Pump (Optional)
The built-in drain pump can lift condensation water up to 700mm high from the drainage pan.
High Static-Pressure
Adjustable static pressure from 0 Pa to maximum 160Pa.
Flexible Installation
Air intake from rear as standard, from bottom is optional. The size of the plate from bottom is the same as the flange from back, which makes it convenient to change installation style due to different decoration requirements.
Self-adaption technology
Automatic ESP Adjustment function will adapt the unit to any ducting with optimized air volume and minimized noise level automatically, making more comfortable in any situation.
Cassette
Built-In Drain Pump
The built-in drain pump can lift condensation water up to 1200mm high from the drainage pan.
Fresh Air Intake
Fresh air makes indoor air healthy and comfortable
|
- High cooling effect
- Super air volume
- Environmental protection and energy saving
- Purification
| Features
- 1. Various products and wide application
The series of Rooftop units include many different specifications which can completely meet the demand of home and
commercial places and offer you a comfortable and pleasant environment.
2. Complete air system, simple and hygiene, less components, easy maintenance
The flexible and concise design makes the maintenance very simple. Disassembling several bolts from any side of the unit
can repair any part of the unit.
3. Microcomputer intelligent controller can reach four control modes: cooling, dehumidifying, and ventilation. It also has
the functions of timing on-off and failure display.
4. Excellent performance
World well-known brand of main parts are used. To guarantee the rational match of the unit, strict performance testing
is done. Besides the unit runs steady and the vibration and noise are effectively controlled by the use of multi-vane pitch
centrifugal fan, world-known high efficiency compressor and the elaborative-designed controller, motor, etc.
5. Quiet operation and Convenient maintenance
Reach the lowest noise of the a/c room. The a/c units are placed far from the a/c area which meets the demand of indoor
low noise to the greatest degree. The adoption of high efficiency and low noise centrifugal fan makes the quiet operation
come true
Free cooling logic:
- When it is cooling:
a. When indoor room temperature (temperature set) – outdoor temperature ≥ 4 ℃,fresh air damper is 100% open,
and return air damper is 100% closed,only the evaporator fan is running to blow air into room;
b. When 0 ℃ ≤ indoor room temperature (temperature set) – outdoor temperature< 4 ℃ ,both fresh air damper
and return air damper are closed, and the unit is not running;
c. When indoor room temperature ( temperature set) – outdoor temperature < 0℃,the return air damper is 100%
open,and fresh air damper is 100% closed,then the compressor, condensing fan and evaporator fan will work normally
to blow cool air into room.
- When it is heating:
It operate in similar way as for free cooling.
Optional heat recovery
Available with a hygroscopic or non-hygroscopic rotor for recovering and transferring
heat energy from the exhaust to the supply air streams.
Optional filter
G3 aluminium filter is standard, optional preliminary, medium filter are
optional.
Optional supply air outlet and return air inlet at the unit bottom
It is optional to have the supply air outlet and return air inlet at
bottom.
Optional MEPS efficiency
It is optional to have the units with efficiency as per MEPS standard.
Dimension
IQRTU72, 96, 125
NOTES:
1. Unit installation hole 4xΦ12.5;
2. Unit lifting hole 4xΦ35;
3. Control box ;
4. Power supply cable inlet hole Φ22;
5. Communication cable inlet hole Φ16;
6. Drain water pipe diameter 1".
IQRTU168, 180
NOTES:
1. Unit installation hole 4xΦ12.5;
2. Unit lifting hole 4xΦ35;
3. Control box ;
4. Power supply cable inlet hole Φ22;
5. Communication cable inlet hole Φ16;
6. Drain water pipe diameter 1".
IQRTU210, 250
NOTES:
1. Unit installation hole 4xΦ12.5;
2. Unit lifting hole 4xΦ45;
3. Control box ;
4. Power supply cable inlet hole Φ35;
5. Communication cable inlet hole Φ22;
6. Drain water pipe diameter 1".
IQRTU300, 360
NOTES:
1. Unit lifting hole 4xΦ50;
21. Unit installation hole 4xΦ12.5;
3. Power supply cable inlet hole Φ45;
4. Communication cable inlet hole Φ16;
5. Control box ;
6. Drain water pipe diameter 1".
IQRTU415, 480, 520
NOTES:
1. Unit lifting hole 4xΦ50;
21. Unit installation hole 4xΦ12.5;
3. Power supply cable inlet hole Φ35;
4. Communication cable inlet hole Φ16;
5. Control box ;
6. Drain water pipe diameter 1".
IQRTU630,750
NOTES:
1. Unit lifting hole 4xΦ50;
2. Unit installation hole 4xΦ12.5;
3. Power supply cable inlet hole Φ50;
4. Communication cable inlet hole Φ16;
5. Control box ;
6. Drain water pipe diameter 1".
IQRTU1023
NOTES:
1. Unit lifting hole 4xΦ50;
2. Unit installation hole 8xΦ12.5;
3. Power supply cable inlet hole Φ80;
4. Communication cable inlet hole Φ16;
5. Control box ;
6. Drain water pipe diameter 1". |
-
- STERILIZATION
- HEALTHY
- COMFORTABLE
- INTELLIGENT
- SAFE
- EFFICIENCY
Directly Install PCB
the Motherboard is easy to disassemble and assemble: the Motherboard can be disassemble without removing the middle frame, which is convenient to disassemble and assemble, and the maintenance efficiency is improved by 50%.
Fluoride Leakage Protection
It can Monitor the Leakage of Freon. when leakage occurs, the Control system will immediately shut down so as to protect core components such as compressors from damage.
High temperature sterilization at 57 °C
The evaporator tube temperature maintains a high temperature of 57 °C and lasts for a period of time to ensure the sterilization effect.
Smarter control, More Energy-saving
0.3W stand by
with newly designed PCB, the 0.3W Standby mode enable IQ Products to cut energy consumption from 4-5W to 0.3W, compared with conventional air conditioners.
Intelligent Power Consumption
Users can set the expected power consumption and power consumption mode for a period of time in the APP, and the air conditioner will automatically adjust the power con sumption after it is turned on; After setting, the air conditioner will execute according to the above objectives, adopting intelligent control algorithm, reasonable cold output.
|
-
- STERILIZATION
- HEALTHY
- COMFORTABLE
- INTELLIGENT
- SAFE
- EFFICIENCY
Directly Install PCB
the Motherboard is easy to disassemble and assemble: the Motherboard can be disassemble without removing the middle frame, which is convenient to disassemble and assemble, and the maintenance efficiency is improved by 50%.
Fluoride Leakage Protection
It can Monitor the Leakage of Freon. when leakage occurs, the Control system will immediately shut down so as to protect core components such as compressors from damage.
High temperature sterilization at 57 °C
The evaporator tube temperature maintains a high temperature of 57 °C and lasts for a period of time to ensure the sterilization effect.
Smarter control, More Energy-saving
0.3W stand by
with newly designed PCB, the 0.3W Standby mode enable IQ Products to cut energy consumption from 4-5W to 0.3W, compared with conventional air conditioners.
Intelligent Power Consumption
Users can set the expected power consumption and power consumption mode for a period of time in the APP, and the air conditioner will automatically adjust the power con sumption after it is turned on; After setting, the air conditioner will execute according to the above objectives, adopting intelligent control algorithm, reasonable cold output.
|